Fabrikaparça

Zander Aachen MINOS SLxE - EN 50156-1 - Minos S Lx E En 50156 1 Safe Firing

Zander Aachen

Ürün Kodu: MINOS SLxE - EN 50156-1
Marka: Zander Aachen

Teklif Al! info@fabrikaparca.com

Zander Aachen MINOS SLxE - EN 50156-1 - Minos S Lx E En 50156 1 Safe Firing için Açıklama:

MINOS SLxE are safety emergency stop modules for monitoring emergency stop buttons, safety doors and light curtains, as well as contact reinforcement of safe outputs (e.g. safe PLC outputs) to machines and plants.

The modules are also certified for continuous operation in furnaces according to EN 50156-1 as well as EN 746-2. For use in the process industry these modules are certified according to IEC 61511-1.

SLxE: Variant for max. requirements up to PL e / SILCL 3 (according to EN ISO 13849-1 bzw. IEC 62061). Test pulses at the safe output enable error detection during operation.

SL1E for dual-channel emergency stop circuit, safety door monitoring with short circuit monitoring

SL2E for light curtains, OSSD output or single-channel emergency stop

There are variants with manual start or auto-start.

These Module are available with screw terminals or tensile spring terminals.

MINOS SLxE
Safety functionSafety emergency stop, safety doors, light curtains, contact reinforcement, OSSD, continous operation of furnaces , stopp category 0
Certified according toEN ISO 13849-1; IEC 62061; IEC 61508; EN 50156-1; EN 746-2IEC 61511-1; EN 60204-1
ApprovalsCE, TUV
Supply VoltageUB: DC 24 V (+/- 10 %)
Power consumption at UB = 24V2.4 W (module enabled via S11. No load)
Number dual-channel inputs1
Number start input1 (auto-start or manual start each variant)
Max. switching capacity O1 ut UB.max. 2.5 A (see derating in the operating instructions)
Maximum switching capacity auxiliary output C1max. 100 mA
Max. switch-on delay10 ms
Off-delay (if requested via the safety circuit)< 13 ms
Ambient temperatur-15 °C to 55 °C (see derating in the operating instructions)
ProtectionIP20
Mounting35 mm DIN-rail
PL; Kat.; SILCL (EN ISO 13849-1; EN 62061)PL e; SILCL 3
Dimension6.2 x 93.1 x 102.5 mm
Weight50 g
Manual Start:
MINOS SL1E, tensil spring terminal, manual start472820
MINOS SL1E, screw terminal, manual start472821
MINOS SL2E, tensil spring terminal, manual start472824
MINOS SL2E, screw terminal, manual start472825
Auto-Start:
MINOS SL1E, tensil spring terminal, auto-start472822
MINOS SL1E, screw terminal, auto-start472823
MINOS SL2E, tensil spring terminal, auto-start472826
MINOS SL2E, screw terminal, auto-start472827

Zander Aachen MINOS SLxE - EN 50156-1 - Minos S Lx E En 50156 1 Safe Firing için önerilen ürünler:


Zander Aachen ZCode-TCE - Coded Stainless Steel Safety Switch
Zander Aachen ZCode-RC - Coded Safety Switch
Zander Aachen Elevator Series - Elevator - Safe Carriage
Zander Aachen MVisio-IO Module - HMI Visualization with PLC
Zander Aachen KL - Micro Switch
Zander Aachen AS - Micro Switch
Zander Aachen ZCode-MCF - Coded Stainless Steel Safety Switch
Zander Aachen DSRC - Interfacemodule
Zander Aachen SCB-02 - Safety Timer
Zander Aachen SCB-03 - Safety Timer
Zander Aachen TB-I14O3 up to 99 h - Compact Safety Controller
Zander Aachen SK3D Coupling/Extension - Safe Coupling Relay
Festo DSM-T-8-180-P-FW - - 1564669
Festo HMSV-51 - - 548781
Festo VMPAL-ZAS-245 - - 561122
T-T Electric LAK 4112B - DC Motor
Festo HEE-3/4-D-MAXI-24 - - 172950
Festo VSVA-B-T32H-AH-A2-1C1 - - 547067
Gefran LM-C-0550 - LINEAR TWIIST
Festo AMTE-M-LH-M3 - - 1231120
Goldammer NTR 85-SR45-T1-A-FE-L370-01-L1/250/S-T10Ö-III-M12 - Level - Temperature - Capillary tube – Regulator
Air Dimensions R061- Metric - R-Series Dia-Vac® Pump Heated Head Hazardous Area
Martens 7122 - Tube Surface Probe
Honsberg OMNI-RRI - Flow Transmitter / Switch