Fabrikaparça

Zander Aachen MINOS SLxD - EN 50156-1 - Minos S Lx D En 50156 1 Safe Firing

Zander Aachen

Ürün Kodu: MINOS SLxD - EN 50156-1
Marka: Zander Aachen

Teklif Al! info@fabrikaparca.com

Zander Aachen MINOS SLxD - EN 50156-1 - Minos S Lx D En 50156 1 Safe Firing için Açıklama:

MINOS SLxD are safety emergency stop modules for monitoring emergency stop buttons, safety doors and light curtains, as well as contact reinforcement of safe outputs (e.g. safe PLC outputs) to machines and plants.

The modules are also certified for continuous operation in furnaces according to EN 50156-1 as well as EN 746-2. For use in the process industry these modules are certified according to IEC 61511-1.

SLxD: Variant for max. requirements up to PL d / SILCL 2 (according to EN ISO 13849-1 bzw. IEC 62061). Test pulses at the safe output enable error detection during operation.

SL1D for dual-channel emergency stop circuit, safety door monitoring with short circuit monitoring

SL2D for light curtains, OSSD output or single-channel emergency stop

There are variants with manual start or auto-start.

These Module are available with screw terminals or tensile spring terminals.

MINOS SLxD
Safety functionSafety emergency stop, safety doors, light curtains, contact reinforcement, OSSD, continous operation of furnaces , stopp category 0
Certified according toEN ISO 13849-1; IEC 62061; IEC 61508; EN 50156-1; EN 746-2IEC 61511-1; EN 60204-1
ApprovalsCE, TUV
Supply VoltageUB: DC 24 V (+/- 10 %)
Power consumption at UB = 24V2.4 W (module enabled via S11. No load)
Number dual-channel inputs1
Number start input1 (auto-start or manual start each variant)
Max. switching capacity O1 ut UB.max. 2.5 A (see derating in the operating instructions)
Maximum switching capacity auxiliary output C1max. 100 mA
Max. switch-on delay10 ms
Off-delay (if requested via the safety circuit)< 13 ms
Ambient temperatur-15 °C to 55 °C (see derating in the operating instructions)
ProtectionIP20
Mounting35 mm DIN-rail
PL; Kat.; SILCL (EN ISO 13849-1; EN 62061)PL d; SILCL 2
Dimension6.2 x 93.1 x 102.5 mm
Manual Start:50 g
Manueller Start:
MINOS SL1D, tensil spring terminal, manual start472800
MINOS SL1D, screw terminal,manual start472801
MINOS SL2D, tensil spring terminal, manual start472804
MINOS SL2D, screw terminal, manual start472805
Auto-Start:
MINOS SL1D, tensil spring terminal, auto-start472802
MINOS SL1D, screw terminal, auto-start472803
MINOS SL2D, tensil spring terminal, auto-start472806
MINOS SL2D, screw terminal, auto-start472807

Zander Aachen MINOS SLxD - EN 50156-1 - Minos S Lx D En 50156 1 Safe Firing için önerilen ürünler:


Zander Aachen ZCode-TC - Coded Safety Switch
Zander Aachen ZCode-LR RFID - Coded RFID Safety Switch
Zander Aachen EPR16S - Cam Controller
Zander Aachen SRTC - Time-delayed Safety Extension Module
Zander Aachen ZX09A - High-Speed-Controller
Zander Aachen ZCode-CCE - Coded Stainless Steel Safety Switch
Zander Aachen ZCode-MCF - Coded Stainless Steel Safety Switch
Zander Aachen ZX09-Series - High-Speed-Controller
Zander Aachen DHC - Timer and Control Relay
Zander Aachen DVC - Timer and Control Relay
Zander Aachen TB-I14O3 up to 990 s - Compact Safety Controller
Zander Aachen SR3AD - Safe Firing
Festo DSL-40-100-270-P-A-S2-B - - 556558
Unimec RY 350 - Bevel Gearbox
Gefran TC5 V - THERMOCOUPLES
ETP 1/4"x50/ISO40 - HYDRO-GRIP PENCIL
HFB DFI 35 - Housed Bearing Units
Festo SIEA-M12B-UI-S - - 538292
Festo VZWF-L-M22C-N2-500-3AP4-6 - - 1492357
Festo NPFB-D-G18-G38-M - - 547802
Tractel 245259 - Minifor SY Series
Festo MHP1-AS-3-M3-PI - - 197186
Solberg HDL-PSG848-126HC - Oil Mist Discharge Filters
Festo HNC-80 - - 174373