Standards
Class 1 or 2 Group X according to IEC 61672-1:2013
Approval according to IEC 61672-1:2002 (I.N.RI.M. Approval Certificate No. 07-0124-02)
Class 1 or 2 according to IEC 60651:2001 and IEC 60804:2000
½” microphone UC52 (or UC52/1) condenser type, pre-polarized, for free field
Dynamic range 30 dBA ÷ 143 dB Peak
Linearity range 80 dB
Acoustic parameters Spl, Leq, LeqI, SEL, LEP,d
, Lmax, Lmin, Lpk, Dose, Ln
Frequency weightings Simultaneous A, C, Z (only C and Z for Lpk)
Time weighting Simultaneous FAST, SLOW, IMPULSE
Integration From 1s to 99 hours with Back-Erase function
Statistical analysis
It displays up to 3 percentile levels, between L1 and L99
Probability distribution and percentile level calculation from L1 to L99 ( HD2010.O2 “Advanced data logger” option)
• Parameter: LFp
, Leq, Lpk , A, C or Z - weighted (only C or Z for Lpk)
• Sampling frequency: 8 samples/second
Classification: Classes of 0.5 dB
Analysis of events
(Option HD2010.O2)
• Calculation of 5 freely-programmable event parameters
• Calculation of statistical levels from L1 to L99
• Event identification trigger with programmable threshold and duration filter
• Manual trigger
Profile data logging
(Option HD2010.O2)
Parallel acquisition of profiles, reports and events
1 profile with sampling 1
/8 s and 3 profiles with 2 samples/second, 5 parameters profiles in Report mode with minimum sampling interval 1s.
Display
Graphic backlit LCD display 128 x 64
• 3 parameters in numeric format
• Profile LAFp with 8 samples/second (option HD2010.O2 “Advanced Data Logger”)
• Graph of sound level probability distribution (option HD2010.O2 “Advanced Data Logger”)
• Graph of percentile levels from L1
 to L99 (option HD2010.O2 “Advanced Data Logger”)
Memory
• Internal, equal to 8 MB for more than 500 records. If the HD2010.O2 option “Advanced Data Logger” is installed, with 8 MB it is
possible to record 1 parameter PROFILE @1/8 s + 3 parameter SLM @ 1/2 s for more than 40 hours.
• External, via the HD2010MC memory card interface, using SD cards up to 2 GB
Input/Output
• RS232 serial and USB interfaces
• AC output (LINE)
• DC output
PC programs
Noise Studio (provided with the instrument): PC interface for data download, set up and instrument management
Licensed software modules to be enabled by hardware key:
• NS1 - “Workers protection” module. Analysis of noise and vibrations in the workplace according to UNI 9432 and ISO 9612 and
2003/10/CE and 2002/44/CE directives.
• NS2A - “Acoustic pollution” module. Analysis of environmental noise. Analysis of the noise climate and assessment of noise from
road, rail and airport according to the law. (requires option HD2010.O2).
• NS4 - “Monitor” module. PC based real time acquisition. Remote monitoring and data capture. Remote connection also via Modem.
The program allows programming of measurements and calibrations with timer and performs events audio recording with
programmable triggers levels.
• NS5 - ”Environmental Noise” module: environmental noise analysis. Noise sources identification with threshold conditions and
impulsiveness evaluation. Some of the functions require HD2010.O2 option.
Operating conditions Working temperature -10…50 °C, 25…90% RH (not condensing), 65…108 kPa. Protection degree: IP64
Power supply 4.8 V / 2.1 A NiMH rechargeable battery or external 5÷24 Vdc / 500 mA
Dimensions and weight 445 x 100 x 50 mm equipped with preamplifier, 740 g (with batteries)

Delta OHM HD40.1 - Class 2 Integrating Sound Level Meter için önerilen ürünler:


Delta OHM HDWME - Class 2 Integrating Sound Level Meter
Delta OHM HD35ED17P TC - Wireless Data Logger System
Delta OHM P7 - RH Probes Protection
Delta OHM TP755 - K Thermocouple Surface Probe
Delta OHM TP741 - K Thermocouple Immersion Probe
Delta OHM HD 25.2 - Bench top Turbidimeter
Delta OHM LPPAR01 - Photosynthetically Active Radiation Probe
Delta OHM LP471PAR02 - PAR Quantum Radiometric Probe
Delta OHM HD52.3D17 - 2 Axis Ultrasonic Anemometer
Delta OHM LPPYRA03AC - Spectrally Flat Class C Pyranometers
Delta OHM HD2013-DB - Rain Indicator Data Logger
Delta OHM HD5014bNTV - Particulate Matter Web Data Logger
ETP 12/HSK63F - HYDRO-GRIP G3
Festo QSL-V0-1/8-4 - - 132891
Festo FRCS-1-D-DI-MAXI - - 194984
Tractel 260909 - Dynafor Industrial 6.3T
Bollfilter 1940562 - Seal
Festo QST3-6-4 - - 153203
Gefran 650-D-R00-01030-0-G - CONTROLLERS AND PROGRAMMERS
Festo VSVA-B-M52-MZD-A1-1T1L - - 539159
Festo DNC-80-500-PPV - - 163458
Festo DSM-T-16-270-CC-A-B - - 1145094
Indexator 80-184 HD - Single swing damper
Festo VN-30-H-T6-PI5-VI6-RO2 - - 526142