Fabrikaparça

Delta OHM HD2010UC/A.Kit2 - Class 2 Integrating Sound Level Meter And Analyzer

Delta OHM

Ürün Kodu: HD2010UC/A.Kit2
Marka: Delta OHM

Teklif Al! info@fabrikaparca.com

Delta OHM HD2010UC/A.Kit2 - Class 2 Integrating Sound Level Meter And Analyzer için Açıklama:

Standards
Class 1 or 2 Group X according to IEC 61672-1:2013
Approval according to IEC 61672-1:2002 (I.N.RI.M. Approval Certificate No. 07-0124-02)
Class 1 or 2 according to IEC 60651:2001 and IEC 60804:2000
Class 1 according to IEC 61260:1995 and IEC 61260-1:2014
Type 1 or 2 according to ANSI S1.4-1983 and S1.43-1997
Class 1-D, order 3, Extended range according to ANSI S1.11-1986
½ inch Microphone UC52 condenser type, pre-polarized, for free field
Dynamic Range 30 dBA ÷ 143 dB Peak
Linearity range 80 dB
Acoustic Parameters Spl, Leq, LeqI, SEL, LEP,d, Lmax, Lmin, Lpk, Dose, Ln
Frequency Weightings Simultaneous A, C, Z (only C and Z for Lpk)
Time Weighting Simultaneous FAST, SLOW, IMPULSE
Integration From 1s to 99 hours with Back-Erase function
Spectrum Analysis
Parallel CPB filters in real time complying with class 1 specifications according to IEC 61260
• Octave bands from 32 Hz to 8 kHz
• Third octave bands from 25 Hz to 12.5 kHz (“Third Octave” option)
Average spectrum (AVR) mode – Multi-spectrum in “REPORT” mode
Statistical Analysis
It displays up to 3 percentile levels, between L1 and L99
Probability distribution and percentile level calculation from L1 to L99
• Parameter: LFp, Leq, Lpk A, C or Z -weighted (only C or Z for Lpk)
• Sampling frequency: 8 samples/second
Classification: Classes of 0.5 dB
Combined Data
logging
Parallel profiles, reports, events acquisition
Record of measuring reports with programmable intervals from 1 s to 1 hour with a customizable set of 5 parameters, complete
statistical analysis and frequency spectra.
Analysis of events
• Calculation of 5 freely-programmable event parameters
• Average spectrum calculation by octave and third octave bands
• Calculation of statistical levels from L1 to L99
• Event identification trigger with programmable threshold and duration filter
• External and manual trigger
Reverberation Time
(option HD2010.O4)
Reverberation time measurement using sound source interruption or impulse response integration
Reverberation time calculation in 1/3 octave requires option HD2010.O1 “Third Octave”.
Profile Data Logging 1 profile with sampling 1
/8 s and 3 profiles with 2 samples/second, 5 parameters profiles in “Report” mode with minimum sampling interval 1s.
Spectrum Data
Logging
Programmable sampling from 1 second to 1 hour (AVR mode). Multi-spectrum data logging in “Report” mode with minimum
sampling interval 1s.
Display
Graphic backlit LCD display 128 x 64
• 3 parameters in numeric format
• Profile LAFp with 8 samples/second
• Octave band spectrum from 32 Hz to 8 kHz
• Third octave band spectrum from 25 Hz to 12.5 kHz (option “Third Octave” )
• Graph of sound level probability distribution
• Graph of percentile levels from L1
 to L99
Memory Internal, equal to 8 MB (4 profiles for 23 hours or over 23 recording days of 3 parameters + spectra per minute)
External, via the HD2010MC memory card interface, using MMC or SD cards up to 2 GB
Input/Output
• RS232 serial and USB interfaces
• AC output (LINE)
• DC output
PC Programs
Noise Studio (supplied with the instrument): PC interface for data download, set up and instrument management.
Licensed software modules to be enabled by hardware key.
• NS1“Workers protection” module. Analysis of noise in the workplace in accordance with ISO 9612/2011 and UNI 9432/2011.
• NS2A“Acoustic pollution” module. Analysis of environmental noise. Analysis of the noise climate and assessment of noise
from road, rail and airport according to the law. Some of the functions need option “Third octaves”.
• NS3“Acoustic Insulation” module. Evaluation of airborne sound insulation, impact noise and sound absorption; buildings
insulation classification (UNI 11367). Some of the calculation require option “Third octaves” and option “Reverberation
time” installed in the sound level meter. Calculation according to ISO 16283, ISO 717 and ISO 354.
• NS4 “Monitor” module. Acquisition in real time on PC. Synchronized audio recording. Remote monitoring and data capture.
Connection via Modem.
• NS5”Environmental Noise” module: environmental noise analysis. Noise sources identification with threshold conditions.
Tonality and impulsiveness evaluation. Some of the functions require „Third octave“ option.
Operating Conditions Working temperature -10…50 °C, 25…90% RH (not condensing), 65…108 kPa. Protection degree: IP64
Power Supply 4.8 V / 2.1 A NiMH rechargeable battery or external 5÷24 Vdc / 500 mA
Dimensions and
weight
445 x 100 x 50 mm equipped with preamplifier, 740 g (with batteries)

Delta OHM HD2010UC/A.Kit2 - Class 2 Integrating Sound Level Meter And Analyzer için önerilen ürünler:


Delta OHM HD501NB…I…TCV - Particulate Matter Web Data Logger
Delta OHM MC22E - Pre-Polarized Random Incidence Condenser Microphone
Delta OHM LP 471 RAD - Radiation Probe
Delta OHM HD50N/1TC - Web Data Logger
Delta OHM TP472I.5 - Penetration Probe
Delta OHM HD2010MC - Class 2 Integrating Sound Level Meter
Delta OHM HD402T/ST/AT1 - Low Pressure Transmitters
Delta OHM HD29V3T - Active Air Speed Transmitters
Delta OHM HD2010.OE - Class 2 Integrating Sound Level Meter
Delta OHM LPPYRA12ACS4 - Spectrally Flat Class B Pyranometers with Shadow Ring
Delta OHM HD2010.SFI8 - Class 1 Integrating Sound Level Meter and Analyzer
Delta OHM HDMCS-200 - All-in-One Meteo Compact Station
Greisinger GES175-BNC - Insertion Probe
Honsberg UR1-015AP - Flow Switch
Festo DRRD-25-180-FH-PA - - 1359980
Festo SMTO-1-NS-S-LED-24-C - - 151686
Festo ADNGF-100-20-PPS-A - - 577226
Tractel TU-32A - Tirfor TU-P Series Pneumatic Wire Rope Winch
Holmatro HFJ 10/30 G 4 - Telescopic Cylinder
Festo AEVULQZ-40-5-P-A - - 157139
Honsberg Nivofix MWI-025HM Level Switch -
Bollfilter 9905859 - Start Plated Filter Element (ıtem22)
Solberg 230P - Replacement Elements
ETP 40/60-95 - HYDRO-GRIP C