Fabrikaparça

Delta OHM HD2010UC/A.Kit1 - Class 2 Integrating Sound Level Meter And Analyzer

Delta OHM

Ürün Kodu: HD2010UC/A.Kit1
Marka: Delta OHM

Teklif Al! info@fabrikaparca.com

Delta OHM HD2010UC/A.Kit1 - Class 2 Integrating Sound Level Meter And Analyzer için Açıklama:

Standards
Class 1 or 2 Group X according to IEC 61672-1:2013
Approval according to IEC 61672-1:2002 (I.N.RI.M. Approval Certificate No. 07-0124-02)
Class 1 or 2 according to IEC 60651:2001 and IEC 60804:2000
Class 1 according to IEC 61260:1995 and IEC 61260-1:2014
Type 1 or 2 according to ANSI S1.4-1983 and S1.43-1997
Class 1-D, order 3, Extended range according to ANSI S1.11-1986
½ inch Microphone UC52 condenser type, pre-polarized, for free field
Dynamic Range 30 dBA ÷ 143 dB Peak
Linearity range 80 dB
Acoustic Parameters Spl, Leq, LeqI, SEL, LEP,d, Lmax, Lmin, Lpk, Dose, Ln
Frequency Weightings Simultaneous A, C, Z (only C and Z for Lpk)
Time Weighting Simultaneous FAST, SLOW, IMPULSE
Integration From 1s to 99 hours with Back-Erase function
Spectrum Analysis
Parallel CPB filters in real time complying with class 1 specifications according to IEC 61260
• Octave bands from 32 Hz to 8 kHz
• Third octave bands from 25 Hz to 12.5 kHz (“Third Octave” option)
Average spectrum (AVR) mode – Multi-spectrum in “REPORT” mode
Statistical Analysis
It displays up to 3 percentile levels, between L1 and L99
Probability distribution and percentile level calculation from L1 to L99
• Parameter: LFp, Leq, Lpk A, C or Z -weighted (only C or Z for Lpk)
• Sampling frequency: 8 samples/second
Classification: Classes of 0.5 dB
Combined Data
logging
Parallel profiles, reports, events acquisition
Record of measuring reports with programmable intervals from 1 s to 1 hour with a customizable set of 5 parameters, complete
statistical analysis and frequency spectra.
Analysis of events
• Calculation of 5 freely-programmable event parameters
• Average spectrum calculation by octave and third octave bands
• Calculation of statistical levels from L1 to L99
• Event identification trigger with programmable threshold and duration filter
• External and manual trigger
Reverberation Time
(option HD2010.O4)
Reverberation time measurement using sound source interruption or impulse response integration
Reverberation time calculation in 1/3 octave requires option HD2010.O1 “Third Octave”.
Profile Data Logging 1 profile with sampling 1
/8 s and 3 profiles with 2 samples/second, 5 parameters profiles in “Report” mode with minimum sampling interval 1s.
Spectrum Data
Logging
Programmable sampling from 1 second to 1 hour (AVR mode). Multi-spectrum data logging in “Report” mode with minimum
sampling interval 1s.
Display
Graphic backlit LCD display 128 x 64
• 3 parameters in numeric format
• Profile LAFp with 8 samples/second
• Octave band spectrum from 32 Hz to 8 kHz
• Third octave band spectrum from 25 Hz to 12.5 kHz (option “Third Octave” )
• Graph of sound level probability distribution
• Graph of percentile levels from L1
 to L99
Memory Internal, equal to 8 MB (4 profiles for 23 hours or over 23 recording days of 3 parameters + spectra per minute)
External, via the HD2010MC memory card interface, using MMC or SD cards up to 2 GB
Input/Output
• RS232 serial and USB interfaces
• AC output (LINE)
• DC output
PC Programs
Noise Studio (supplied with the instrument): PC interface for data download, set up and instrument management.
Licensed software modules to be enabled by hardware key.
• NS1“Workers protection” module. Analysis of noise in the workplace in accordance with ISO 9612/2011 and UNI 9432/2011.
• NS2A“Acoustic pollution” module. Analysis of environmental noise. Analysis of the noise climate and assessment of noise
from road, rail and airport according to the law. Some of the functions need option “Third octaves”.
• NS3“Acoustic Insulation” module. Evaluation of airborne sound insulation, impact noise and sound absorption; buildings
insulation classification (UNI 11367). Some of the calculation require option “Third octaves” and option “Reverberation
time” installed in the sound level meter. Calculation according to ISO 16283, ISO 717 and ISO 354.
• NS4 “Monitor” module. Acquisition in real time on PC. Synchronized audio recording. Remote monitoring and data capture.
Connection via Modem.
• NS5”Environmental Noise” module: environmental noise analysis. Noise sources identification with threshold conditions.
Tonality and impulsiveness evaluation. Some of the functions require „Third octave“ option.
Operating Conditions Working temperature -10…50 °C, 25…90% RH (not condensing), 65…108 kPa. Protection degree: IP64
Power Supply 4.8 V / 2.1 A NiMH rechargeable battery or external 5÷24 Vdc / 500 mA
Dimensions and
weight
445 x 100 x 50 mm equipped with preamplifier, 740 g (with batteries)

Delta OHM HD2010UC/A.Kit1 - Class 2 Integrating Sound Level Meter And Analyzer için önerilen ürünler:


Delta OHM HD2109.1 - Oxygen Meter-Thermometer
Delta OHM HD2030AC4 - T-Shaped Hand-Arm Adapter
Delta OHM HD208 - Compact Data Logger: Monitoring Temperature, RH and Dew Point
Delta OHM HD2021T1 - Photometric Radiometric Transmitters
Delta OHM LPPHOT02 - Photometric Probe for Illuminance
Delta OHM HD35ED14bNAB - Wireless Data Logger System
Delta OHM TP652 - K Thermocouple Immersion Probe
Delta OHM HDBV-1000 - Building Vibration Kit
Delta OHM HD35ED1N/2 TC - Wireless Data Logger System
Delta OHM HD32.2.7.1 - Probes Holder
Delta OHM LPPYRA02AC - Spectrally Flat Class B Pyranometer
Delta OHM HD501NTC - Web Data Logger
Festo SPC200-DIO - - 170179
Seim PXF045 Triple Screw Pump -
Festo CECX-D-8E8A-NP-2 - - 552099
Scherzinger 4050-710-DM-110-2-Exe - Titanium Gear Pumps 4050
Gefran MX - MELT - HIGH TEMPERATURE
Festo EAMK-A-S38-38A/B - - 558171
Festo ADN-12-40-A-P-A - - 536210
Ebara CMD 2.00. T - Centrifugal Pump
Festo DNC-80-320-PPV - - 163456
Festo ADN-16-25-A-P-A - - 536223
Festo DSNU-16-15-PPS-A - - 1908275
Bollfilter 4302210 - Control Unit