Barksdale's 420X Series Explosion Proof Transducers prevent an explosion from occurring when operated in a Division 1 environment. Barksdale's 420X Series transducers prevent personal injury and machinery damage by preventing the explosion the first place. Energy generated within the transducer is of such a low level that intermittently present flammable vapors will not be ignited. External zener barriers are not required in order to meet UL requirements for a non-incendive installation. The lower cost of not having to install zener barriers means that the positive aspects of intrinsically safe and explosion proof are combined in Barksdale non-incendive transducers. Three models are available: Series 423X (0-5V), Series 425X (4-20mA) and Series 426X (0-10V).

General Specifications*

Accuracy (LH & R):±0.25% FSO at 75°F (±0.5% for vacuum only [-23]) typical
Long Term Stability:±0.5% FSO of calibration curve
Typical Life Cycle:100 million cycles
Proof Pressure:2 times rated pressure or 13,000 psi max. (884 bar), whichever is less
Input: 423X: 426X: 425X: Excitation voltage: 11 to 30 VDC Excitation voltage: 14 to 30 VDC Excitation voltage: 12 to 28 VDC
Supply Current:3.0 mA maximum (no load)
Output: 423X: 426X: 425X: Output: 0.5 to 5.5 VDC Full scale output: 5.0 VDC ± 1% Zero output: 0.5 VDC ± 2% Output: 1 to 11 VDC Full scale output: 10 VDC ± 1% Zero output: 1.0 VDC ± 2% Output: 4 to 20 mA Full scale output: 16 mA ± 1% Zero output: 4 mA ± 2%
Wetted Parts:17-4 PH (fitting)** & 300 series stainless steel (sensor)
Enclosure:NEMA 4X, 300 series stainless steel
Pressure Connection:1/4”-18 NPT male
Electrical Connection:3 conductor for voltage series and 2 conductor for current series, 24 awg, PVC jacketed, shielded cable, 3 ft. (1 m) long with integral strain relief and case ground (standard).
Temperature Ranges: Operating: Compensated: Storage: -40° to 185°F (-40° to 85°C) 0° to 160°F (-18° to 71°C) -40° to 185°F (-40° to 85°C)
Temperature Shift: Zero & Span: 0.0125% per °F over compensated range reference
Vibration:15 g’s, 10-2000 Hz, MIL-STD 202
Shock:50 g’s, 11 mS, MIL-STD 202 Method 213, Cond. G.
Approvals: All: 425X only:cULus approved as telemetering equipment for use in hazardous locations (UL File E146589, WYMV, WYMV7) as follows: Class I, Div. 1, Groups A, B, C & D Class II, Groups E, F & G. ATEX/IECEx Certification: CE 0081 Ex II 2 G D, Ex d IIC 91°C (T5) Gb, Ex tb IIIC T100°C Db IP66, -40°C ? Tamb ? 85°C, DEMKO 04 ATEX 0334369, IECEx UL 13.0036X
Weight: 423X & 426X: 425X: 7.4 oz. (221 grams) to 1000 psi 9.9 oz. (281 grams) 2,000 psi and higher 7.4 oz. (210 grams) to 1000 psi 9.4 oz. (266 grams) 2,000 psi and higher
Warranty:1 year warranty
* See product confi gurator for additional options. ** Consult factory for 316SS option.

Wiring Code

MILLIVOLT SERIES - 423X & 426X
CableSignal
Red+ Excitation
White+ Output
BlackCommon
BareDrain
MILLIAMP SERIES - 425X
Red+ Excitation
Black- Excitation
BareDrain

Barksdale Series 423X, 425X, 426X - Series 423 X, 425 X, 426 X Explosion Proof Transducer (Amplified) için önerilen ürünler:


Barksdale T9692X - Compact Explosion Proof Temperature Switch
Barksdale CDPD1H, CDPD2H, VCDPD1H, VCDPD2H Series - Calibrated Differential Switch
Barksdale Series 450X - Intelligent Transmitter
Barksdale Series III-L Valves - Actuated Heavy Duty
Barksdale Series THR, THL - Temperature Switch
Barksdale UM-200 - 2- Channel Universal Monitor
Barksdale Series II - 14, 18, 92, 376, 20, 562 - Actuated Heavy Duty Valves
Barksdale Series T1X, T2X, L1X - Explosion Proof Temperature Switches
Barksdale UNS1000-BN18 - Level Switch/Temperature Option
Barksdale UDS7-BX - Explosion Proof Electronic Pressure Switch
Barksdale 52334 Series - Atlas Valve
Barksdale Model 20597 - Heavy Duty Hydraulic Regulator
Greisinger GTO 130 OK - Probe's thermocouples
Honsberg UK.-040G.W0014 - Flow Meter
Festo VN-10-H-T3-PI4-VI4-RO1 - - 193509
Festo HMVO-POT - - 539973
Festo SOE4-FO-D-HF2-1P-M8 - - 552799
Festo SOEG-RSP-Q50-NA-K-3L - - 537764
Gefran 650-D-RR0-01011-1LFG - CONTROLLERS AND PROGRAMMERS
Greisinger USB5100 - Interface Converter
Gefran ME-B07C - MELT - HIGH TEMPERATURE
Industrie technik VFPIM25-1500 - VFPIx - Pressure independent control valves
Psp pohony C3P-200 - Parallel shafts triple reduction gearbox without electric motor
ETP 12x150/C6 - HYDRO-GRIP PENCIL